Digital Monitoring Products XTL/XTLC Installation Guide
6
InstallatIon
Wireless Keypads
11.1 Mounting Keypads
DMPkeypadshaveremovablecoversthatallowthebasetobemountedonawall,deskstandorotherat
surface using the screw holes provided on each corner.
11.2 Wireless Keypad Association
EnableWirelessKeypadAssociationoperationonboththekeypadandpanel.
Toenableassociationoperationinthekeypad,accesstheInstallerOptionsMenu(3577(INST)).Thekeypad
logoLEDsturnoffuntilassociationissuccessful.
Toenableassociationoperationinthepanel,presstheRESETbutton3timeswithin12secondsallowing3
secondsbetweeneachpressoftheresetbutton.Wheninkeypadassociation,theRedandGreenlogoLEDs
turn on steady.
For60secondsthepanellistensforwirelesskeypadsthatareintheInstallerOptionsMenu(3577CMD)and
havenotbeenprogrammed,orassociatedintoanotherpanel.Thosekeypadsareassignedtotherstopen
devicepositionautomaticallybasedupontheorderinwhichtheyaredetected.ThekeypadlogoturnsGreen
to indicate it has been associated with the panel.
Wireless Zones
12.1 Description
XTL/XTLCpanelsprovide28wirelesszonesnumbered1to28.Adefaultzonename,zonetype,andarea
assignmentaredescribedintheXTL/XTLCProgrammingGuide(LT-1108)andcanbechangedinZone
Information programming as needed. The defaults are provided as a programming convenience to help
reduce installation time.
Wireless Key Fobs and Outputs
13.1 Description
XTL/XTLCpanelsprovide8wirelesskeyfoboroutputaddressesnumbered31to34and41to44.Adefault
name is provided as a programming convenience to help reduce installation time. The default names are
describedintheXTL/XTLCProgrammingGuide(LT-1108)andcanbechangedinOutputInformationorZone
Information programming as needed.
Flash Load Button
14.1 Description
TheXTL/XTLCpanelsoftwarecanbeupdatedviathepanel’sprogramming(PROG)header.Toupdatethe
panel with a new software version, complete the following steps at the protected premise:
Model 399 Cable
1.ConnectaDMP399CablefromtheProgrammingHeadertotheserialportofyourPCoperatingRemote
LinkandcontainingtheXTLRUle.
2.StartRemoteLinkandcreateoropenthecontrolpanelaccountthatmatchesthepaneltobeupdated.
3.SettheConnectionInformationTypetoDirectwithabaudrateof38400andchoosetheappropriate
COMport.
4.SelectPanel>RemoteUpdate,thenselectthecorrectRUleforthepanel.
5.PressandholdtheLOADbutton(S2),thenpressandreleasetheRESETbutton.
6.ReleasetheLOADbuttonandclick<Update>inRemoteLink.
7.Afterthesoftwareupdateiscompleted,removethe399cableandpresstheRESETbuttontoresume
normal panel operation.
Model 400 USB Flash Module
1.PressandholdtheLoad(S2)switch.WhileholdingtheLoad(S2)switch,pressandreleasetheReset(S1)
switch
2.ReleasetheLoad(S2)switch.
3.ConnecttheUSBashdrivetotheModel400andconnecttheassemblytothepanelsProgramming(J8)
header.TheLEDontheModel400willashanddisplaysteadygreen.
5.PressandreleasetheloadbuttonontheModel400toinitiatethermwareupdate.TheLEDonmodel
400willashslowly.IftheLEDdisplaysfastashesitmeansthermwareupdatewasunsuccessful.
6.Theupdatewilltakeapproximately4.5minutesandwhencompletetheLEDontheModel400will
display steady green.
7.PressandreleasetheReset(S1)switchthenremovetheUSBashdriveandModel400assembly.For
additionalinformationseeModel400USBFlashModuleInstallationGuide(LT-1402).