11
6. TROUBLE SHOOTING
1) If the system does not work?
Check the main breaker-ON in the control box.
Check the ELB ON in the operation breaker.
Check the power lamp-ON at Power s/w ON.
Check the Ready lamp ON.
Check the Main Electric power 380V (in case of 3 Phase 4 wired)
Check the operating power 220V.
2) If not watering
Check the power s/w lamp
Check the watering valve open
Check the 380V on main breaker
Check the watering (solenoid) valve
Check power on floatless sensor
Check the lamp off after clean the sensor if floatless sensor lamp on.
3) If not quit watering
Clean the floatless sensor
Clean the solenoid valve
Check the floatless sensor lamp on
4) If dish is not clean after wash
Remove dregs at the wash nozzle
Check the tripper up on wash contactor
Remove the dregs in wash pump
Check the leakage and short of wash pump
Push the tripper after check wash pump
Check 380V on wash pump contactor by voltage tester
Check the water is full in wash tank, otherwise fill up the water into
the wash tank after its leakage.
Check the wash temperature, 55℃~65
Check the chemical agent feeding, automatically
If lower temperature, check the temperature controller and contactor
5) If rinse is not good
Check if the water pressure, 1.2Kg/ over
Clean dregs on the rinse nozzle
Check rinse temperature, 82

Related product manuals