11
6. TROUBLE SHOOTING
1) If the system does not work?
◎ Check the main breaker-ON in the control box.
◎ Check the ELB ON in the operation breaker.
◎ Check the power lamp-ON at Power s/w ON.
◎ Check the Ready lamp ON.
◎ Check the Main Electric power 380V (in case of 3 Phase 4 wired)
◎ Check the operating power 220V.
2) If not watering
◎ Check the power s/w lamp
◎ Check the watering valve open
◎ Check the 380V on main breaker
◎ Check the watering (solenoid) valve
◎ Check power on floatless sensor
◎ Check the lamp off after clean the sensor if floatless sensor lamp on.
3) If not quit watering
◎ Clean the floatless sensor
◎ Clean the solenoid valve
◎ Check the floatless sensor lamp on
4) If dish is not clean after wash
◎ Remove dregs at the wash nozzle
◎ Check the tripper up on wash contactor
◎ Remove the dregs in wash pump
◎ Check the leakage and short of wash pump
◎ Push the tripper after check wash pump
◎ Check 380V on wash pump contactor by voltage tester
◎ Check the water is full in wash tank, otherwise fill up the water into
the wash tank after its leakage.
◎ Check the wash temperature, 55℃~65℃
◎ Check the chemical agent feeding, automatically
◎ If lower temperature, check the temperature controller and contactor
5) If rinse is not good
◎ Check if the water pressure, 1.2Kg/㎠ over
◎ Clean dregs on the rinse nozzle
◎ Check rinse temperature, 82℃