12
CCC Ducted Installation Instructions
A. 520, 530, 579, 590, 591 AND 595 SERIES
1. Insert the Freeze Control Sensor approximately 1" into the ns of the evaporator coil as shown in FIG. 9. Bend
ns over sensor to secure in place.
2. Plug the freeze control sensor cord into the mating connector on the Electronic Control Kit. These connectors are
polarized and will easily snap together. DO NOT FORCE.
8. INSTALLATION OF COLD CONTROL
B. 600 & 630 SERIES
1. Insert the Freeze Control Sensor approximately 1" into the evaporator coil ns located at the right side of the
evaporator, as shown in FIG. 10. Bend ns over sensor to secure in place.
2. Plug the freeze control sensor cord into the mating connector on the Electronic Control Kit. These connectors are
polarized and will easily snap together. DO NOT FORCE.
8. WIRING OF CONTROL SYSTEM
A. CONNECTION OF 115 VAC SUPPLY
1. Reach up into the return air opening of the air conditioner and pull the unit electrical cord down for later installation.
See FIG. 11.
AC Power
Supply
Pull Electrical
Cord Down
Roof
Gasket
FIG. 11
Disconnect 115 VAC. Failure to follow these
instructions could create a shock hazard caus-
ing death or severe personal injury.
This product is equipped with a 3-wire
(grounded) system for protection against
shock hazard. Make sure that the appliance
is wired into a properly grounded 115 VAC
circuit and the polarity is correct. Failure to
do so could result in death, personal injury
or damage to the equipment.