EasyManua.ls Logo

Dometic AirCon ASC 2000 - User Manual

Dometic AirCon ASC 2000
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AirCon Service Center
ASC1000 / ASC2000 / ASC2000RPA / ASC3000
DE 3 Klima-Service-Station
Bedienungsanleitung
EN 49 Air conditioning service unit
Operating manual
NL 95 Airco-servicestation
Gebruiksaanwijzingen
DA 142 Klimaservicestation
Betjeningsanvisning
SV 187 Klimatservicestation
Bruksanvisning
ASC_RPA_de_en_nl_da_sv.book Seite 1 Dienstag, 5. Februar 2008 3:10 15

Questions and Answers

  • H
    Heidi MclaughlinSep 23, 2025
    What does 'Error 06' mean on my Dometic Air Conditioner (ASC2000RPA only)?
    • T
      Taylor WoodwardSep 23, 2025
      If the Dometic Air Conditioner (ASC2000RPA only) displays 'Error 06', it means the pressure is too high at connection (8) for the nitrogen bottle. Set the pressure regulator on the external nitrogen bottle to max. 12 bar.
  • A
    Andrew GreenAug 23, 2025
    What to do if my Dometic AirCon ASC 2000 displays 'A/C system leakage! Continue?'
    • J
      Julia HaleyAug 23, 2025
      If the Dometic Air Conditioner displays 'A/C system leakage! Continue?', it indicates a vacuum loss of more than 120 mbar during the checking time at the end of the vacuum process. You should check the air conditioning system or the connections between it and the AirConServiceCenter for leaks.
  • N
    Nicholas Gonzalez DVMAug 25, 2025
    Why does my Dometic AirCon ASC 2000 Air Conditioner display 'Ext. tank empty or closed valve! Check!'?
    • A
      Aaron MurphyAug 26, 2025
      The Dometic Air Conditioner displays 'Ext. tank empty or closed valve! Check!' because the set refrigerant quantity cannot be attained at the start or during the filling of the internal refrigerant container. Check if the external refrigerant container still contains enough refrigerant or if the valves of the external refrigerant container are open.
  • M
    Melanie GibbsAug 27, 2025
    What does it mean when my Dometic AirCon ASC 2000 Air Conditioner displays 'Not enough refrigerant. Add.'?
    • C
      Courtney MayAug 27, 2025
      When the Dometic Air Conditioner displays 'Not enough refrigerant. Add.', it means that there is not enough refrigerant in the internal container to complete the process. To fix this, fill the refrigerant container.
  • J
    Joseph StoneAug 27, 2025
    Why does my Dometic AirCon ASC 2000 show 'Warning ! Not enough vacuum for injection!'?
    • T
      Trevor MatthewsAug 28, 2025
      The Dometic Air Conditioner displays 'Warning ! Not enough vacuum for injection!' during the filling phase because the vacuum in the air conditioning system is insufficient to end the process. Check the air conditioning system or the connections between it and the AirConServiceCenter for leaks.
  • K
    Kathryn CrawfordSep 18, 2025
    What does 'Error 05' mean on my Dometic Air Conditioner (ASC2000RPA only)?
    • A
      ashley34Sep 18, 2025
      If the Dometic Air Conditioner (ASC2000RPA only) displays 'Error 05', it means the pressure is too low at connection (8) for the nitrogen bottle. Set the pressure regulator on the external nitrogen bottle to max. 12 bar. Replace the bottle if it is empty.
  • H
    hmartinSep 15, 2025
    What does 'Warning ! Internal vessel overpressure.' mean on my Dometic AirCon ASC 2000 Air Conditioner?
    • J
      Jessica ThomasSep 15, 2025
      The message 'Warning ! Internal vessel overpressure' on your Dometic Air Conditioner is normal during the recycling process. To continue, press ENTER for three seconds. If the message appears more than once, inform a technician.
  • J
    Jason CarrSep 17, 2025
    What to do if Dometic AirCon ASC 2000 displays 'Error 03' and refrigerant scales show '-9999 kg'?
    • K
      Kelsey ReynoldsSep 17, 2025
      If the Dometic Air Conditioner displays 'Error 03' and the refrigerant scales show '-9999 kg', it means the transport lock has not been removed. Undo the knurled screw of the transport lock on the bottom of the AirConServiceCenter as far as it will go.
  • C
    Crystal WatersSep 6, 2025
    What to do if Dometic AirCon ASC 2000 Air Conditioner displays 'Drained oil glass emptying.'?
    • D
      David ThompsonSep 6, 2025
      If the Dometic Air Conditioner displays 'Drained oil glass emptying.' during the extraction or recycling process, it means there is more than 150 ml of used oil in the container. You should dispose of the content of the used oil container in an environmentally responsible manner.
  • M
    Meagan BellSep 4, 2025
    What does 'Error 02' mean on my Dometic AirCon ASC 2000 Air Conditioner?
    • B
      bpayneSep 4, 2025
      If the Dometic Air Conditioner displays 'Error 02', it means the air conditioning system is leaking and there is still refrigerant in the system. You should fix the leak.

Summary

Scope of delivery

Safety

General safety instructions

Provides essential safety guidelines and precautions for operating the AirCon Service Center safely.

Warnings on the AirCon Service Center

Highlights specific warnings and symbols related to the device's operation and potential hazards.

Safety devices

Explains the built-in safety mechanisms like pressure monitors and relief valves for user protection.

Proper use

First start-up

Setting up and switching on

Guides users through the initial physical setup and power-on procedure for the AirCon Service Center.

Filling up the internal refrigerant container

Provides instructions for the initial filling of the internal refrigerant container from an external tank.

Operation

Short selection

Introduces the fully automatic service mode, detailing the sequence of actions performed.

Free selection

Describes the menu for step-by-step servicing, allowing process selection and customization.

Flushing the air conditioning system

Instructions for flushing the system, suitable for replacing oil or removing residue.

Service tasks

Calibrating the scales (only ASC2000, ASC2000 RPA and ASC3000)

Guides on regularly checking and resetting scale zero points for accurate measurements.

Troubleshooting

Technical data

Dometic AirCon ASC 2000 Specifications