A. Choosing Proper Location For Unit
This unit is specically designed for installation on the roof
of a Caravan. When determining your cooling requirements,
the following should be considered:
● Size of Caravan;
● Window area (increases heat gain);
● Amount of insulation in walls and roof;
● Geographical location where the Caravan will
be used;
● Personal comfort level required.
1. Normal locations - The unit is designed to t
over an existing roof vent opening.
2. Other locations - When no roof vent is available
or another location is desired, the following is
recommended:
a. For one unit installation: The unit should be
mounted slightly forward of center (front to
back) and centered from side to side.
b. For two unit installations: Install one unit 1/3
and one unit 2/3’s from front of Caravan and
centered from side to side.
It is preferred that the unit be installed on a relatively at and
level roof section measured with the Caravan parked on a
level surface. See table below for maximum acceptable tilt.
Type
Number
Max
Tilt
3242 8°
After Location Has Been Selected:
c. Check for obstructions in the area where unit
will be installed. See (FIG. 1).
FIG. 1
Dimensions Are Nominal
241 mm
737 mm
1016 mm
Keep These Areas
Free Of Obstructions
Roof
Opening
Front
Center Line Of Unit
102 mm
102 mm
305 mm
Type
3242
d. Maintain structural integrity.
Otherwise damage to product and/or Cara-
van could occur.
The roof must be designed to support 60
kg when the Caravan is in motion. Normally
a 91 kg static load design will meet this re-
quirement.
e. Check inside the Caravan for air distribution
box (hereinafter referred to as "ADB") ob-
structions (i.e. space for doors to open, room
dividers, curtains, ceiling xtures, etc.). See
(FIG. 2).
FIG. 2
587 mm
537 mm
67 mm
Dimensions Are Nominal
294.5 mm 294.5 mm
537 mm
87.5 mm
87.5 mm
73 mm
152 mm
Roof Opening