CB, RHD Technical data
19
13 Technical data
CoolMatic CB36, CB40 and RHD50 cooling devices all have the following features:
• Connection voltage 12 V DC or 24 V DC
• Relative humidity: maximum 90 %
• Constant inclination: max. 30°
CB36 CB40
Capacity: 36 l 40 l
Power consumption: 45 W 45 W
Cooling temperature range: +10 °C to –12 °C
Coolant quantity: 60 g
CO2 equivalent: 0.086 t
Dimensions (WxHxD) in mm
(with compressor):
fig. 1, page 3 fig. 2, page 3
Weight: 17 kg 19 kg
RHD50
Capacity: 50 l
Power consumption: 45 W
Cooling temperature range: +10 °C to +2 °C
Coolant quantity: 35 g
CO2 equivalent: 0.05 t
Dimensions (WxHxD) in mm
(with compressor):
fig. 3, page 3
Weight: 20 kg
RHD-CB--O-West.book Seite 19 Dienstag, 29. November 2016 11:52 11