10 Troubleshooting
If the system detects an error, it switches off independently. The toolbar and the display bar are
hidden.
Source
Error
code
Possible cause Possible Solution
DSP E-01 Battery undervoltage Charge the battery.
E-02 Battery overload Reduce the input voltage.
E-03 Inverter overload Reduce the connected load.
E-04 –
E-05
Overheating of the
inverter
Ensure sufficient air supply at the inverter.
E-06 Initialisation error Contact customer service.
E-07 Uninterrupted power
supply is not present
Activate the inverter function (chapter
“Switching inverter on/off” on page 15).
Check the connection to the mains power
supply.
Display E-16 CI bus does not
respond
Check the BUS cabling of the battery sensor.
E-17 DSP-T does not
respond
Set the main switch to REMO.
Check the BUS cabling of the DSP-T
inverter.
E-19 MCA does not respond Check the BUS cabling to the MCA charger.
E-20 Battery charging status
too low
Charge the battery.
'63(0,2VERRN6HLWH'LHQVWDJ0DL

Table of Contents

Other manuals for Dometic DSP-EM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic DSP-EM and is the answer not in the manual?

Dometic DSP-EM Specifications

General IconGeneral
BrandDometic
ModelDSP-EM
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals