Cleaning and caring for the inverter SinePower
16
9.4 Configuring the net configuration
D
Using the dip switch you can define in which net configuration the inverter shall
operate.
10 Cleaning and caring for the inverter
A
Occasionally clean the product with a damp cloth.
DANGER!
Changing the net configuration results in risk of lethal injury.
The dip switch must only be set by qualified personnel.
Remove the the dip switch‘s protection cap for configuring only. Insert
the protection cap to prevent switching the dip switch‘s setting.
Parameter Dip switch
TN grid
An external downstream circuit breaker (RCD) is
necessary.
On
IT grid
Operation with one load only or installation of an
external insulation monitor.
National standards shall apply!
Off
NOTICE!
Do not use sharp or hard objects or cleaning agents for cleaning as these
may damage the product.