See fig. 5
Before installation, check whether the roof hole needs reinforcing.
Remove the foam according to the width of your reinforcing rails (not in scope of
delivery) (A).
Fit the reinforcing rails (B).
8.3 Installing in a roof hatch opening already provided
I
See fig. 6
Remove all screws and fixtures of the existing roof hatch.
Take out the roof hatch.
See fig. 7
Remove the sealant around the opening using a scraper or similar tool.
See fig. 8
A
Seal the screw holes and recesses with a flexible non-hardening butyl sealing
compound (e.g. SikaLastomer-710).
NOTE
Existing roof hatch openings in accordance with fig. 3 are suitable
for installing the roof air conditioner.
Dispose of all waste material, glue, silicone and seals separately.
Observe the disposal guidelines.
The manufacturer only assumes liability for parts included in the
scope of delivery. The validity of the warranty expires if the device is
installed together with third-party parts.
NOTICE!
Observe the sealant manufacturer’s instructions.