L-2091 Operation
Condensing unit BTU extraction capacities at normal operating
conditions with air and water condensing enabled, and a -10°F
evaporating surface.
Notes:
(1) Capacities found at the following conditions:
Air/Water and 2 psi – -10
°
F Evaporating and 100
°
F Condensing
Air/Water and 12 psi – 10
°
F Evaporating and 100
°
F Condensing
Air only and 2 psi – -10
°
F Evaporating and 120
°
F Condensing
Air only and 12 psi – 10
°
F Evaporating and 120
°
F Condensing
For 50/60 Hz units, use on 50 Hz decreases capacity by 17%.
(2) All units are Air/Water capable, however, the water condenser
may not be used in some instances.
Compressor Evaporating Air/Water Air Cooled
Horsepower Pressure Cooled Only
(2)
1/4HP 2 psi 1495 1170
12 psi 2440 1880
3/8HP 2 psi 1980 1545
12 psi 3230 2485
1/2HP 2 psi 2405 1860
12 psi 4165 3425
Capacity (in BTU/Hr)
(1)