EasyManua.ls Logo

Dometic ProSafe MD283 - Page 29

Dometic ProSafe MD283
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Troubleshooting proSafe
30
ERROR B A code cannot be
entered.
The safe is blocked if it
has been closed and
opened again
20 times within
10 minutes.
Wait for 6 minutes with-
out pressing any buttons.
The lock is no longer
disabled following this
6 minute waiting period.
Following this, enter the
correct code.
Open the door mechani-
cally with the master key.
The master key will not
turn.
Wrong key Check that the key
number is the correct
one.
Wrong direction Turn the key 180° in a
clockwise direction.
The safe does not func-
tion (no audible signal,
no display message).
The battery is low. Replace the batteries.
The batteries are not
inserted correctly.
Check whether the
batteries are correctly
inserted.
Display Fault Possible cause Suggested remedy
MD-IO-16s.book Seite 30 Freitag, 4. August 2017 9:25 09