EasyManua.ls Logo

Dometic RM 4203 - ELECTRICAL CONNECTION; 230 V Supplies; 12 V Supplies

Dometic RM 4203
16 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A
flexible tube/hose, of max 1,5 m length approved for LPG
i
s connected to the threaded nipple (J) of fig. 6. Its other
e
nd is connected to the reducing valve of the gas bottle as
s
hown in 8 ig. 9 or to an easily accessible gas shut off valve
w
hich forms a part of the fixed gas installation of the buil-
d
ing.
.
.. in vehicles
T
he gas supply pipe should be connected to the gas inlet
p
ipe on the right hand side of the gas control valve by
m
eans of a suitable threaded coupling.
I
n making the connection to the refrigerator, a gas cock of
a
n approved type for use on LPG must be incorporated in
t
he supply line in a position which is readily accessible to
t
he user. For eventual servicing purposes, the union should
b
e on the outlet side of the cock and the pipework should
b
e positioned so as not to prevent the refrigerator from
b
eing readily withdrawn.
E
LECTRICAL CONNECTION
T
he electrical installation must be carried out in a proper
a
nd durable manner, taking into account all relevant regu-
l
ations and codes of practice. For mains voltage operation,
i
t is important that the circuit to and in the caravan is effec-
t
ively earthed.
A
LL MAINS VOLTAGE WIRING IN THE CARAVAN
M
UST BE INSTALLED IN ACCORDANCE WITH
C
URRENT I.E.E. REGULATIONS INCLUDING THE USE
O
F AN OUTLET AND COUPLER TO BS4343/- CEE17.
F
or connection to a 230 V electricity supply, the refrige-rator
h
as a 3-core mains lead which is intended for connec-tion to
a
properly earthed plug and socket outlet.
I
MPORTANT: The wires in the mains lead of this appliance
a
re coloured in accordance with the following code:
G
REEN-AND-YELLOW = EARTH
B
LUE = NEUTRAL
B
ROWN = LIVE
A
s the colours of the wires may not correspond with the
c
oloured markings identifying the terminals in your plug, in
t
he United Kingdom, proceed as follows:
T
he wire which is coloured GREEN-AND-YELLOW must be
c
onnected to the terminal in the plug which is marked with
t
he letter E or by the earth symbol or coloured green
o
r green-and-yellow.
T
he wire which is coloured BLUE must be connected to the
t
erminal which is marked with the letter N or coloured black.
T
he wire which is coloured BROWN must be connected to
t
he terminal which is marked with the letter L or coloured
r
ed.
W
ARNING - THIS APPLIANCE MUST BE EARTHED.
I
n the United Kingdom, the plug or circuit to the refrigerator
m
ust be fitted with a fuse not greater than 5 amps. If a 13
a
mp.(B.S.1363) fused plug is used, it should be fitted with a
3
amp. fuse. In other countries, the fuse rating will depend
u
pon the voltage and local practice.
2
30 V Supplies.
C
heck that the voltage stated on the data plate is the same
a
s the mains voltage in use (230 V).
1
2 V Supplies
C
onnect the refrigerator to the vehicle battery or alterna-tor
b
y a direct cable. To avoid a voltage drop, the cross-section
a
rea of the connecting cable between battery/alter-nator
a
nd refrigerator must be at least 2.5 mm
2
if the distance is
l
ess than 9 meters, and at least 4 mm
2
if the distance is
m
ore than 9 meters
T
o ensure satisfactory operation, the positive lead must be
f
itted with a fuse rated at max. 16 A.
T
o prevent the refrigerator from draining the battery, make
s
ure that the current supplied to the caravan is cut off when
t
he vehicle engine is not running, for example by fit-ting an
i
gnition control relay.
W
iring diagram, see fig. 8.
T
he notations in the wiring diagramme are:
I. Diagramme for the mains installation.
II. Diagramme for the 12 V installation.
S. 12 V heating element
T. Switch for 230 V/12 V operation
U. Electric thermostat
V. Heating element, 230 V
Electrical leads
must be routed and secured so that they cannot come
into contact with hot or sharp parts of the refrigerator.
12