REFRIGERATORS WITH
BOTTOM
MOUNT CONTROLS
Refrigerators with Piezo lgnitors
(RM2310
&
RM2410)
A
-
ON/OFF Switch
B
-
Thermostat Gas/Electric
c
-
Safety Push-button
D
-
Piezo lgnitor
E
-
Flame View Port
Refrigerators with Automatic Reigniters
(RM251
O/RM261
O/RM2610)
A
-
ON/OFF Switch
B
-
Thermostat, Gas/Electric
c
-
Safety Push-button
E
-
Light
GAS OPERATION
Refrigerators with
Piezo lgnitor (RM2310
&
RM2410)
To start the
refrigerator, turn knob
“A”
to the “GAS”
position.
Turn the thermostat knob
“B”
one-quarter
(l/4)
of a turn from the “OFF” position.
Push button
“C”
in until it bottoms out-and hold. While holding button “C”, push button “D” for the
piezo ignitor several times to light the burner. This can be observed through the flame view port,
“E”,
on the refrigerator.
After the flame lights, continue to hold button “C” for an additional fifteen (15) seconds. Release the
button “C” and check the flame view port
“E”
to make sure the burner does not go out. If the burner
goes out, repeat the lighting procedure.
To shut off the refrigerator, turn Knob “A” to the “OFF” position.
Refrigerators with Automatic Reigniters (RM2510
/RM2610
/RM2810)
To start the refrigerator, turn knob “A” to the “GAS” position.
Turn the thermostat knob
“6”
one-quarter
(l/4)
of a turn from the “OFF” position.
Push button “C” in until it bottoms out-and hold. When lamp
“E”
stops flashing, hold push-button “C”
an additional 15 seconds. Release button “C”. If the lamp
“E”
starts to flash again, repeat lighting
procedure. If flame blows out, the reigniter will automatically relight the flame.
4