Operating the generator TEC60EV
18
8.7 Checking the oil level
!
I
Always check the oil level before use. To do this, proceed as follows:
➤ Open the generator flap.
➤ Switch the generator to no function with the main switch (fig. 4 1, page 4).
➤ Disconnect the positive terminal of the supply battery.
➤ Take the dipstick (fig. 4 2, page 4) out of the filler neck (fig. 4 3, page 4).
➤ Clean the dipstick (fig. 4 2, page 4) with a cloth.
➤ Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3, page 4).
➤ Take the dipstick (fig. 4 2, page 4) out of the filler neck.
Engine lost comm
The generator stops. Check the system by referring to
the troubleshooting table.
If the problem persists, contact
the manufacturer's branch office
in your country (see back page).
Inverter failed
The generator stops. Contact the manufacturer's
branch office in your country (see
back page).
Eng. Param. Error
The generator stops. Contact the manufacturer's
branch office in your country (see
back page).
Inv. Param. Error
The generator stops. Contact the manufacturer's
branch office in your country (see
back page).
Software Error
The generator stops. Contact the manufacturer's
branch office in your country (see
back page).
CAUTION! Risk of injury
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
NOTE
The generator must be level.
Display message
Description
Generator behaviour Measures