Servicing the generator TEC60EV
20
I
10.2 Preparing maintenance work
!
➤ Open the generator flap.
➤ Switch the generator to no function with the main switch (fig. 2 1, page 3).
➤ Disconnect the positive terminal of the supply battery.
For maintenance work, you can take the generator out (fig. 5, page 5):
!
➤ Undo the fastening screws (1).
➤ Remove the mounting plate (2) with the generator from the housing (3).
NOTE
Have the following maintenance work performed at regular intervals or
after the specified number of operating hours, whichever is sooner.
Interval Inspection/maintenance
In the first month
or after 20 hours.
➤ Change the oil.
➤ Check the air filter (chapter “Servicing the air filter” on page 22).
Every 3 months or
after 50 hours.
➤ Check the air filter (chapter “Servicing the air filter” on page 22).
Every 6 months or
after 100 hours.
➤ Change the oil.
➤ Check the spark plug (chapter “Servicing the spark plugs” on
page 23).
Once a year or
every 300 hours
➤ Check the valves.
➤ Check the fuel tank and fuel filter.
➤ Check the vibration damper.
Every two years ➤ Check the petrol supply lines.
CAUTION! Risk of injury
Note the following for all maintenance work:
• The generator must not be running.
• All the parts must be cooled down.
WARNING! Risk of injury
The mounting plate with generator is very heavy (> 70 kg) and could fall
out the housing if you take it out too far.