TEC60EV Servicing the generator
21
10.3 Finishing maintenance work
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (fig. 4 1, page 4).
Close the generator flap.
10.4 Changing the oil
!
A
You may use the following oil:
SAE 5W-30 grade oil (can be used at any temperature).
Oil with single grade oil viscosity.
Select the appropriate viscosity according to the average temperature on-site.
Change the oil as follows:
Allow the generator to run until warm so that the oil can drain off faster and
completely.
Place a suitable receptacle under the drain plug (fig. 6 1, page 5).
Remove the dipstick.
Take out the drain plug (fig. 6 1, page 5).
The oil drains off.
Pour fresh oil into the filler neck.
The amount of oil is: 1.1 l.
Put the drain plug in.
CAUTION! Risk of injury
Hot oil can cause burns.
NOTICE! Damage hazard
Only dispose of used oil at a specialist recycling station and observe the
local laws for environmental protection.
TEC60EV-O-16s.book Seite 21 Montag, 5. August 2019 12:56 12

Table of Contents

Other manuals for Dometic TEC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic TEC Series and is the answer not in the manual?

Dometic TEC Series Specifications

General IconGeneral
BrandDometic
ModelTEC Series
CategoryPortable Generator
LanguageEnglish

Related product manuals