TEC29 EV AUS Troubleshooting
45
The generator
tends to stall.
Too much oil in the engine.
➤ Drain the oil.
Load is over 2.6 kW.
➤ Reduce the consumers.
Carburettor is not receiving any
petrol.
➤ Clean the carburettor.
Air intake is blocked.
➤ Check the air filter (see chap-
ter “Servicing the air filter” on
page 42).
Inverter is damaged.
➤ Contact an authorised work-
shop.
Electromagnet is blocked.
Air filter is dirty.
The generator is
running but does
not supply any
voltage.
Inverter is damaged.
➤ Contact an authorised work-
shop.
The stepper motor is faulty or the
cable is disconnected.
Electromagnet is blocked.
The throttle valve is blocked.
The generator
starts up very
fast and then the
“GENERATOR
ALERT”
message
appears.
Generic alarm
➤ If the problem persists, contact
an authorised workshop.
Inverter is damaged.
➤ Contact an authorised work-
shop.
The stepper motor is faulty or the
cable is disconnected.
The generated
voltage is
unstable.
Inverter is damaged.
➤ Contact an authorised work-
shop.
The stepper motor is faulty or the
cable is disconnected.
Fault Cause Remedy