Operating the generator TEC29 EV AUS
36
10.7 Checking the oil level
!
I
Always check the oil level before use. To do this, proceed as follows (fig. i,
page 11):
➤ Open the generator front door.
➤ Switch the generator to no function with the main switch (1).
➤ Disconnect the positive terminal of the supply battery.
➤ Take the dipstick (2) out of the filler neck (3).
➤ Clean the dipstick (2) with a cloth.
➤ Put the dipstick (2) back into the filler neck (3).
➤ Take the dipstick (2) out of the filler neck.
➤ Check that the oil level is between the notch (maximum filling level) and
the tip of the dipstick (4).
If not, top up with more oil.
➤ Put the dipstick (2) back into the filler neck (3).
➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (1).
➤ Close the generator front door.
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
NOTE
The generator must be level.