EasyManua.ls Logo

Dometic TEC29 - Page 20

Dometic TEC29
388 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Operating the generator TEC29, TEC29LPG
20
OVER TEMPERATURE
Overheating
The inverter switches off so no
voltage is supplied to cool the
generator, but the engine car-
ries on running.
Leave the engine to cool down
for a few minutes then start the
generator again.
LOW POWER ENGINE
The inverter supply voltage has
dropped.
The generator stops. Reduce the connected load and
start the generator again.
RESTART GEN?
Message appears after the gen-
erator has stopped due to over-
heating.
The generator is switched off. Press the start button to restart
the generator.
GEN CAL
Message appears when the gen-
erator is started up; it shows the
calibration phase which takes
place before each start-up. The
generator does not supply any
voltage.
The generator is running but
does not supply any voltage.
Wait a moment.
GEN WAIT
Message appears while you are
waiting for the generator to start
again.
The generator is switched off. Wait until the message has disap-
peared then attempt ignition
again.
GEN ON
The generator is operating nor-
mally.
Normal mode
GEN OFF
The generator is in stand-by and
can be started.
AUTO?
Message appears when the
automatic mode is switched on.
Controls are waiting for user
input
Press the start button within
20 seconds and hold down for
3seconds.
AUTO
Automatic mode
The automatic mode is switched
on
Display message
Description
Generator behaviour Measures
TEC29-B-16s.book Seite 20 Donnerstag, 21. Juli 2016 8:09 08

Table of Contents

Other manuals for Dometic TEC29

Related product manuals