EN
TEC29, TEC29LPG Operating the generator
21
8.7 Checking the oil level
!
I
Always check the oil level before use. To do this, proceed as follows:
Open the generator front door.
Switch the generator to no function with the main switch (fig. 4 1, page 5).
Disconnect the positive terminal of the supply battery.
Take the dipstick (fig. 4 2, page 5) out of the filler neck (fig. 4 3, page 5).
Clean the dipstick (fig. 4 2, page 5) with a cloth.
Put the dipstick (fig. 4 2, page 5) back into the filler neck (fig. 4 3, page 5).
Take the dipstick (fig. 4 2, page 5) out of the filler neck.
Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick (fig. 4 4, page 5).
If not, top up with more oil.
Put the dipstick (fig. 4 2, page 5) back into the filler neck (fig. 4 3, page 5).
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (fig. 4 1, page 5).
Close the generator front door.
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
NOTE
The generator must be level.
TEC29-B-16s.book Seite 21 Donnerstag, 21. Juli 2016 8:09 08