DISPLAY DIAGNOSTIC CODES
Diagnostic Service Codes Description Appliance Action User Corrections
E10 Waterlltimeexceeds5
minutes.
Unit will close valves and
stop.
Tap is not open. Check inlet
hoseandlters.
E11 Thereisexcessivewater
left in the unit during unit
standby or end of cycle.
Unit will start pump with
door locked, valve closed,
and motor stopped.
Check outlet hose and
pumplter.
E12 The water level in the drum
exceedsthedesignedlevel.
Unit will start pump with
door locked, valve closed,
and motor stopped.
Check outlet hose and
pumplter.
E21 In three minutes, the water
level doesn't drain with
pump started.
Unit will pause with pump
stopped, door unlocked if
water level is low enough.
Check outlet hose and
pumplter.
E30 Door won't lock in three
tries.
Unit will stop. Check for blockage. Ensure
door is closed.
E31 Door won't unlock in three
tries.
Unit will stop. Continue original cycle to
completion. Allow appliance
to cool. Run a spin cycle.
E70 Button stuck. No function. Check the buttons.
Codes E20, 33-40, 64-81, and all others NOT listed above are an internal fault that MUST becorrectedbyaqualied
service professional. The appliance may NOT work or in a few cases will function but NOT fully as designed. Contact a
Dometic Corporation authorized service representative to repair the appliance.