57
31 Scanhead
temperature
out of valid
range.
The scanhead is
cold.
Restart the system. Contact
Domino.
32 Scanhead
warming up -
please wait.
The scanhead is
cold.
Wait for the heaters in the
scanner motors to warm the
scanners, the printer can be
used but you may
experience very minor
position errors.
33 Control unit
over
temperature.
The temperature in
the controller is very
cold or too hot.
Check that the fans are
working and that the filters
are not blocked.
51 Control unit
near over
temperature.
The controller is
getting quite hot.
Check that the fans are
working and that the filters
are not blocked.
56 Printer ready to
print.
Printer will print if a
print go signal
arrives.
Information Only.
58 No Message
loaded
There is no valid
message loaded
into the controller.
Load a message and send it
to printer.
549 Turn keyswitch
to enable
marking
The safety relay
needs to be set after
an interlock has
been opened.
Turn keyswitch to start
position, or give a remote
start input (the “Play” button
on the UI will not function).
550 System
disabled
The keyswitch is at
position 0.
Turn the keyswitch to
position 1.
551 Aiming turned
on
The aiming beam,
configurable in the
global settings, is
turned on.
Information Only.
Status
Message