Adjustable Settings
We recommend leaving the machine in its factory based sengs.
Should you feel the need to adjust these sengs, please contact
someone on our technical support team for assistance.
Code Seng Name
Range Default Unit
Ice Cream Mode
P0
Firmness Seng
1 to 10 3 Class
P1
Temperature of hopper cooling in ice-cream mode
(-9) to 9
4
°C
P2
Return dierence of temp of hopper cooling
0 to 9 2 °C
P3
Time delay between drive motor & compressor
5 to 60 30 Second
P4
Restarng me of compressor in ice-cream mode
5 to 15 5 Minute
P5
Time delay between fan motor and drive motor
0 to 60 15 Second
Slush Mode
P6
Restarng me of compressor in slush mode
0 to 5 2 Minute
P7
Temperature of freezing cylinder in slush mode
(-1) to (-9) (-5) °C
P8
Return dierence of temperature of freezing cylinder
0 to 9 2 °C
P9
Time delay between drive motor and compressor
0 to 60 30 Second
PA
Extending me for making slush
0 to 30 5 Minute
Table 1.2
Adjustable Settings
We recommend leaving the machine in its factory based sengs.
Should you feel the need to adjust these sengs, please contact
someone on our technical support team for assistance.