P6 - Compressor Restart Timer
This seng represents the maximum number of minutes which
the compressor can be in standby (OFF) before it must restart
and begin cooling the freezing cyclinder.
For example, the compressor will stay on until the temperature of the freezing cylin-
der has reached the "Target Temperature" set in the P7 setting. At that time a timer
will start, and the compressor will continue to stay on for the number of seconds set
in the P9 setting, "Extend Time for Compressor". As soon as that time is reached, the
compressor will shut off and go into standby mode for the number of minutes set in
this P6 setting at which point the compressor will turn back on and repeat this cycle.
Press “SET” buon to enter the P6 seng, press “UP” or “DOWN”
to adjust the temperature from 0 to 5 minutes, press “SET” but-
ton again to save the data and enter into the P7 seng.
SLUSH SETTINGS
To access and make adjustments to sengs P6 - PA, you must be in "Slush
Mode". Press the “SLUSH” buon to enter into the slush mode. Press and
Hold the “UP” and “DOWN” buons simultaneously for 5 seconds, and
“SET” will begin ashing on the display panel. Press the “SET” buon to
scroll through the sengs below.