P7 - Freezing Cylinder Target Temperature
Press “SET” buon to enter the P4 seng, press “UP” or “DOWN”
to adjust the temperature from -9 to 9 minutes, press “SET” but-
ton again to save the data and enter into the P8 seng.
P8 - Return Temperature for Freezing Cylinder
This temperature seng is the delta of P7, Freeze Cylinder Tem-
perature Seng, from which the Temperature of the Freezing
Cylinder must reach before the the Compressor will turn back
on.
For example, if your P7 setting is set to -5°C and this setting is set for 3°C, then
when the compressor is in standby it will not turn back on until the Freezing Cylinder
Temp reaches -2°C, which is a 3 degree difference from the P7 setting of -5°C.
Press "SET” buon to enter the P8 seng. Press “UP” or “DOWN”
to adjust the delta return temperature for the cooling cylinder
from 0 to 9. Press “SET” buon again to save the data and enter
into P9 seng.