P9 - Extend Time for Compressor
This seng represents the number of seconds in which the
compressor will connue to run once the Freeze Cylinder Target
Temperature has been reached, which is set in the PA seng.
For example, if your P7 setting is set to -5°C and this setting is set for 30, as the
compressor is running and cooling the freezing cylinder, when the Freezing Cylinder
Temp reaches the target temperature of -5°C, instead of the compressor shutting
off, it will continue running for 30 seconds, which is represented by the 30 in this
setting.
Press “SETbuon to enter the P9 seng, press “UPor “DOWN”
to adjust this seng between 0 - 60 seconds. Press “SETbuon
again to save the data and enter into the P6 seng.
PA - Extended Time for Initial Freeze
In the inial freeze cycle, once the temperature sensor has de-
tected that the temperature of the freezing cylinder has reached
the Freeze Cylinder Temperature Seng set in "P7", a mer will
start and will allow the compressor to stay on for the number
of minutes set in this "PA" seng. This will allow the mix in the
freezing cylinder to become slushy before the compressor shuts
o and the normal freezing cycle begins.