Maintenance of Major Components
- 177 -
5.5.7. Diagnostics and troubleshooting
Complaints Possible causes
Corrections
1. Engine overheating
Air cleaner element clogged
Replace or clean
Restrictions in air duct
Check and correct
Leakage at intake manifold
Check and correct
Turbocharger seized up and not rotating
Disassemble/repair or replace
Turbine blades and compressor blades
coming in contact with each other or
damaged
Disassemble/repair or replace
Exhaust piping deformed or clogged
Check and correct
2. Engine overcooling
Oil leak into turbine and compressor
Disassemble/repair or replace
Worn or damaged seal ring due to
excessive wear of bearing
Disassemble/repair or replace
3. Lack of coolant
Gas leak at each part of exhaust system
Check and correct
Air cleaner element restricted
Replace or clean
Turbocharger fouled or damaged
Disassemble/repair or replace
Leakage at discharge port on
compressor side
Check and correct
4. Cooling system noisy
Rotor assembly coming in contact
Disassemble/repair or replace
Unbalanced rotation of rotor
Disassemble/repair or replace
Seized up
Disassemble/repair or replace
Each joint loosened
Check and correct