Technical Information
- 42 -
8. Battery discharge
Normal
Battery
Wiring, Switch
Alternator
Check electrolytic liquid amount
Inspect cut wire shorts and
loose connections
Check fan belt tension & damage
Battery room damage
Replenish
Repair
.
Replace
Replce Charging Inspect alternator
voltage regulator
Battery self dischage Battery over charging
Electrolytic
liquid’s standard
Normal
Check charged stated
Discharging
Disassemble alternator
.
Voltage regulator
Abvormal
Adjust
.
Replace