5.1 Program switch
OFF
AUTOMATIC
EXIT ONLY
PERMANENT
OPEN
5.2 “External” key switch (optional)
OFF
5.3 Opening in the event of a power failure
Doors without locking device
Doors with fail-secure locking
Doors with fail-safe locking
5.4 Commissioning following a power failure
5.5 Safety equipment
The emergency off pushbutton, located within the close
range of the door system, has to be unlocked (turn and pull
the button) during commissioning.
The four following function programs can be selected via the
program switch:
The system is switched off.
In case of systems with optional locking
device, the door is locked
electromechanically. The door can be
unlocked and opened manually.
The door opens following activation via an
activator and closes automatically on expiry
of the preset hold-open time.
The hold-open time can be adjusted with the
aid of the potentiometer located at the
control unit (0-30 sec.)
The door can only be activated from the
inside (oneway function e.g. at closing time)
The door closes on expiry of the preset hold-
open time.
this position until another function program
is selected. (e.g. summer operation/
cleaning purposes).
The door can only be opened from the outside while the
program switch is set to .
An opening pulse of approx. 2 sec. has to be triggered by an
external pushbutton.
The door closes on expiry of the preset hold-open time.
The door can be opened manually.
The door can be unlocked and opened with the aid of the
manual lock release.
The door can be opened manually.
The operator starts automatically and performs the adjusted
program switch function.
1. The prescribed force at the main closing edge of the
door is limited to 150 N at the highest according to
the guidelines for power-operated windows, doors and
gates (BGR 232).
2. The motion range of the door leaves is monitored by a
infrared .
As soon as a person or an object is within the
detection range while the door is open, the door travels
to its complete open position. The door remains in this
position until all people/objects are out of the
detection range. The door closes on expiry of the
preset hold-open time.
The door opens and remains in
Presence sensor
3. Dynamic force limitation
The opening and closing speed of the RST has to be
adjusted with the aid of the adjustment valve so that
the dynamic forces comply with DIN 18650.
5.6 Maintenance
DORMA
5.7 Care
OFF PERMANENT OPEN
5.8 DIY rectification of malfunctions
In case all check points are okay, please contact a service
technician.
The system has to be de-energised (disconnected from
power supply) before performing any kind of maintenance
work.
De-energise the door system by switching off the fuse.
Before the first commissioning and depending on
requirements, however, at least once a year, the door system
has to be inspected by a properly qualified technician and
serviced if required.
Please consider the inspection book (WN 056963-45532)
for further information.
The working area has to be secured against unauthorised
access from other people.
Falling items or tools might cause injuries.
We would recommend taking out a maintenance agreement
with .
Set the program switch to or while
cleaning the system in order to avoid that the door moves
unintentionally.
You can clean the whole sliding door system (aluminium,
glass parts, cover) with a damp cloth and a common
cleaning agent.
The has to be cleaned using a dry cloth.
All floor guides have to be kept clean from dirt.
In case the door does not open or close,
please check if:
The power supply is in order.
The program switch is set to the correct position
(function).
The door is locked manually.
The detection range of the is blocked.
The is clean.
The door is blocked by obstacles.
Presence sensor
Presence sensor
Presence sensor
·
·
·
·
·
·
32