ED50LE/ED100LE/ED900 208125350
www.dormakaba.us
T: 717-336-3881
09-2021
Step
Configuration
Parameter
Range
Factory
Settings
* Factory setting.
Installation
type
-
0*
Pull arm with track, wall mounting
on pull (hinge side).
Push arm, wall mounting on
approach (non-hinge side).
Push arm with track, wall mounting
on approach (non-hinge side).
Reveal
depth
- to 0*
Reveal depth rd is set in increments
of mm (/”).
Example: = mm ( /”)
Door width to 10*
The astragal is included in the door
width.
Door width Tb is set in increments
of mm (”).
Example: = mm (”).
Door type to 0* Single door
Reveal depth rd
Door width Tb
rd
Inches
- - /
- -/
- -/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Tb
Inches
Step
Learn Cycle.
A ““ displayed on the right side and a rotating segment
on the left indicates the unit is ready for a learn cycle.
To start the learn cycle, press and hold the bottom button
until the display changes (approximately three seconds).
• The door will make several movements and the display
will cycle through several letters and numbers.
When the display stops at “” push the door open to the
desired opening angle between and degrees, then
let go of the door.
Press the bottom button to continue the learn cycle.
The operator will complete the learn cycle.
• When finished, there will be two horizontal bars side by
side on the display.
You can now continue with the programming and
customize the door as desired.
Spring force too low.
If the door closes and an “F” is displayed, this is an
indication that the spring force is too low.
. Turn off the power.
. Increase the spring force.
• The spring should have a minimum of turns and a
maximum of turns, depending on door width and
weight.
. Restart the learn cycle (Step ).