D25ALN
Manuel d’utilisation
Owners manual
Gebrauchsanweisung
Manuale d’uso
Manual de utilización
Gebruiksaanwijzing
Pуководство пользователя
Instrukcja obsługi
Manual de utilização
DOSATRON INTERNATIONAL S.A.S.
Rue Pascal - B.P. 6 - 33370 TRESSES (BORDEAUX) - FRANCE
Tel. 33 (0)5 57 97 11 11
Fax. 33 (0)5 57 97 11 29/33 (0)5 57 97 10 85
info@dosatron.com - www.dosatron.com
© DOSATRON INTERNATIONAL S.A.S 2017
FABRIQUÉ PAR
MANUFACTURED BY
HERGESTELLT VON
FABBRICATO DA
FABRICADO POR
GEPRODUCEERD DOOR
ИЗГОТОВЛЕНО
PRODUKCJA
FABRICADO POR
NTD25ALN-07-18

Questions and Answers

  • P
    Patricia GarrisonJul 28, 2025
    How to fix a blocked motor piston in a Dosatron Water Pump?
    • J
      Joshua GrayJul 28, 2025
      If the motor piston of your Dosatron Water Pump is blocked, bleed the dosing pump by opening the clear water and fast priming valves situated downstream and upstream of the Dosatron. Then, dismantle the top cap to access the motor piston. Test the motor piston by hand. Activate the valve mechanism by pressing the vertical pushbutton until you hear the valves switch on.
  • T
    Travis RoyAug 7, 2025
    Why is the motor piston not working in my Dosatron Water Pump?
    • J
      Jamie BowersAug 7, 2025
      If the motor piston of your Dosatron Water Pump is not working, first check your water inlet for issues such as no water consumption, supply failure, a clogged filter, or improperly positioned Dosatron By-pass valves. Open the rinsing/fast priming valve downstream of the Dosatron to test the water supply and the operation of the dosing pump. Also, make sure your installation has sufficient minimum pressure. If the water flow is very low, the Dosatron motor may require several minutes to complete a full cycle.
  • L
    Lisa VegaAug 17, 2025
    What to do if there is air in my Dosatron Water Pump?
    • T
      Tyler MccannAug 17, 2025
      If there is air present in your Dosatron Water Pump, bleed the air using the bleed valve found on the top cap. This is especially useful under extremely low water flow and pressure conditions.

Summary

Product Identification and Specifications

Reference Codification

Details on product reference and serial number identification, including engraving and labels.

Technical Characteristics

Specifications including operating flow, pressure, temperature, and dimensions.

Installation Guide

Installation Precautions and Safety

Essential safety measures and general guidelines for installing and operating the Dosatron pump.

Mounting the Dosatron Unit

Step-by-step guide on how to physically mount and connect the Dosatron to the water supply line.

Installation Tips and Best Practices

Recommendations for optimal installation, including bypass assembly and filtering.

Putting into Service

Initial Setup and Priming

Procedures for initial setup, including bleeding and priming the pump for the first use.

Adjusting Dosing Rate

Instructions on how to adjust the dosing percentage or ratio for accurate product delivery.

Dosing Principle Explanation

Explanation of how the Dosatron calculates and mixes the product with water based on flow.

Maintenance Procedures

General Maintenance Recommendations

General advice for maintaining the Dosatron, including rinsing and solubility checks.

Suction Hose Servicing

Step-by-step guide for safely disconnecting and reconnecting the suction hose.

Dosing Part Dismantling and Refitting

Procedures for dismantling and reassembling the main dosing component.

Dosing Part Seal Replacement

Guidance on replacing worn seals to ensure proper function and prevent leaks.

Draining the Dosatron

Instructions on how to empty the pump for maintenance or frost protection.

Dosing Piston Servicing

Detailed steps for disassembling, refitting, and cleaning the dosing piston.

Suction Valve Servicing

Procedures for cleaning and reinstalling the suction valve to prevent leaks.

Motor Piston Servicing

Steps for changing and refitting the motor piston assembly.

Troubleshooting and Problem Solving

Identifying and Resolving Common Issues

Common issues with the Dosatron, their causes, and recommended solutions for troubleshooting.

Limited Warranty Information

Warranty Coverage and Conditions

Information regarding the warranty period, coverage, and conditions for replacement or repair.

Flow Rate Calculation and Performance Data

Calculating Water Flow Rate

Explanation of the Dosatron's mechanism and a method to calculate water flow based on motor piston clacks.

Pressure Drop Performance Curves

Charts illustrating pressure loss at different flow rates and operating conditions.

Viscosity Performance Curves

Charts showing the relationship between product viscosity and operating parameters.

dosatron D25+ Series Specifications

General IconGeneral
ModelD25+ Series
CategoryWater Pump
Dosing Capacityup to 25 L/h
Injection Range0.2% to 6%
Pressure Range0.2 to 6 bar
MaterialsPolypropylene
Connection Size1/2 inch
Flow RateUp to 25 l/h (Varies by model)
Injection Ratio1:100 to 1:10 (Varies by model)
Dosing Accuracy± 5%

Related product manuals