Questions and Answers

  • C
    chadharrisonAug 10, 2025
    What to do if the motor piston is damaged in my dosatron D3 RE 3000?
    • G
      George OchoaAug 10, 2025
      If the motor piston of your Dosatron Water Pump is damaged, and causing the unit to not start or stop, return unit to your service center for repair.
  • J
    Jason DavisAug 20, 2025
    Why does my dosatron D3 RE 3000 stop or not start?
    • J
      Justin CervantesAug 20, 2025
      If your Dosatron Water Pump stops or doesn't start, several issues could be the cause. First, the piston might be stalled; try resetting it manually. Another reason could be that air hasn't been properly bled from the unit; use the bleed button to remove any trapped air. Also, exceeding the maximum flow can cause this issue. In this case, reduce the flow and restart the unit. You can also check the piston valves seals to ensure correct position after unscrewing the top cap and taking off the piston. Finally, a damaged motor piston could be the culprit, requiring a return to the service center for repair.
  • M
    Madison ArmstrongAug 30, 2025
    What to do if water flows back into the concentrate container of my Dosatron Water Pump?
    • K
      karenbrownAug 30, 2025
      If water is flowing back into the concentrate container of your Dosatron Water Pump, here are a few things to check: * Contaminated, worn, or missing check valve parts: Clean or replace them. * Air leak (inlet) in the suction tube: Check the tightness between the nut and suction hose. * Blocked suction tube or clogged strainer: Clean or replace it. * Missing or worn suction check valve seal: Clean or replace it. * Missing or worn plunger seal: Clean or replace it.

dosatron D3 RE 3000 Specifications

General IconGeneral
ModelD3 RE 3000
CategoryWater Pump
TypeDosing Pump
Operating Pressure6 bar
Concentrated additive injectionYes
Flow Rate3000 L/h
Maximum Flow Rate3, 000 L/h
Pressure Range0.5 - 6 bar
Dosing Range0.2 - 6%
Injection Ratio1:100 to 1:10, 000
Temperature Range0 to 40 °C
Connection Size1 inch
MaterialsPlastic, Stainless Steel