Questions and Answers

  • M
    Mary PaceAug 17, 2025
    What causes leaks in the vicinity of the fixing ring under the body housing in dosatron D 25 RE 2 Water Pump?
    • L
      lauriemossAug 17, 2025
      If you notice leaks in the vicinity of the fixing ring under the body housing of your Dosatron Water Pump, it's likely that the injector sleeve seal is damaged or positioned incorrectly. You should replace it.
  • D
    daniel92Aug 19, 2025
    Why is there leaks between the setting sleeve and the blocking ring in dosatron D 25 RE 2 Water Pump?
    • C
      Christian ConnerAug 19, 2025
      If there are leaks between the setting sleeve and the blocking ring in your Dosatron Water Pump, the injector stem seal might be damaged, positioned incorrectly, or missing. Replace it.
  • A
    alexandriariversAug 22, 2025
    How to stop leaks between the body and screw-top of Dosatron Water Pump?
    • J
      jill68Aug 22, 2025
      If you observe leaks between the body and screw-top of your Dosatron Water Pump, the screw-top seal is likely damaged, positioned incorrectly, or missing. To resolve this, unscrew the screw-top, clean the seal seating, and then replace or change the seal. Make sure to position the screw-top correctly afterward.
  • J
    Jennifer HardinAug 26, 2025
    What to do if my dosatron D 25 RE 2 Water Pump has no suction of concentrate?
    • R
      Rachel HunterAug 26, 2025
      If your DOSATRON Water Pump isn't drawing concentrate, several issues could be the cause. First, check the suction tube for any air leaks, ensuring the nut and suction hose are tightly connected. Also, inspect the suction tube and strainer for blockages and clean or replace them if necessary. Furthermore, examine the suction check valve seal and plunger seal for wear or damage, replacing them as needed. Finally, a worn injection stem can also prevent suction, so consider replacing it. If the piston motor has stopped, refer to the Piston motor section.
  • M
    Michelle DavisAug 28, 2025
    Why does my dosatron D 25 RE 2 piston motor not start or stop?
    • A
      April NixonAug 28, 2025
      If the piston motor on your DOSATRON Water Pump won't start or stop, there are several potential causes. A stalled piston can prevent proper operation; try resetting it by hand. Air trapped in the unit can also cause issues, so bleed the air using the bleed button. If the maximum flow is exceeded, reduce the flow and restart the unit. You may also unscrew the screw-top, take off the piston and check piston valves seals to ensure correct position. If the piston motor is damaged or the check valve parts are contaminated, worn, or missing, return the unit to your service center for repair, or clean or replace the check valve parts.
  • C
    Cindy SantosAug 31, 2025
    Why does my Dosatron Water System stop working or not start?
    • T
      terryjacksonAug 31, 2025
      Your Dosatron Water System might stop or fail to start due to several reasons: * The piston may be stalled. You can try to reset the piston by hand. * There might be air trapped inside the unit. Bleed the air using the bleed button. * The maximum flow might be exceeded. Reduce the flow and restart the unit. Also, check the piston valve seals to ensure they are correctly positioned after unscrewing the top cap and removing the piston.
  • B
    Bruce RaySep 2, 2025
    What to do if water flows back into the concentrate container of my Dosatron Water System?
    • S
      Stephen GibbsSep 2, 2025
      If water is flowing back into the concentrate container, it's likely due to contaminated, worn, or missing check valve parts. Try cleaning or replacing the check valve.
  • M
    Michael RyanSep 5, 2025
    How to fix no suction of concentrate in my Dosatron Water System?
    • M
      Michael ValenciaSep 5, 2025
      If your Dosatron Water System isn't drawing concentrate, consider these potential causes: * Check for air leaks in the suction tube, ensuring the nut and suction hose are tightly connected. * A blocked suction tube or clogged strainer could be the issue; clean or replace these parts. * Inspect the suction check valve seal and plunger seal for wear or if they are missing; clean or replace them as necessary. * Also, a worn injection stem may be the cause; replace it.
  • B
    Bonnie MorenoSep 8, 2025
    Why does my dosatron D 25 RE 2 not start or stop?
    • A
      Ann ClarkeSep 8, 2025
      If your Dosatron Water Pump isn't starting or suddenly stops, there could be several reasons. First, the piston might be stalled, in which case you should reset it by hand. Another reason could be that air hasn't been bled from the unit; try bleeding the air using the bleed button. If the maximum flow is exceeded, reduce the flow and restart the unit; also, unscrew the top cap, take off the piston, and check the piston valve seals to ensure they are in the correct position. Finally, if the motor piston is damaged, it should be returned to your service center for repair.
  • A
    Alison JacksonSep 10, 2025
    What to do if water flows back into concentrate container in Dosatron Water Pump?
    • P
      pinedajerrySep 12, 2025
      If water is flowing back into the concentrate container of your Dosatron Water Pump, it could be due to several reasons. The check valve parts might be contaminated, worn, or missing, so you should clean or replace them. An air leak in the suction tube (inlet) might be the cause, so check the tightness between the nut and suction hose. Alternatively, the suction tube might be blocked or the strainer clogged, so clean or replace it. Another possible reason is a missing or worn suction check valve seal, in which case you should clean or replace it.

Summary

Introduction and Important Information

Important Record Keeping

Record model and serial number for service and parts.

How the DOSATRON Works

Installation Precautions

General Safety and Installation Remarks

Regulations, flow direction, non-return valve, anti-siphon valve, acid container, freezing, heat, suction side, seal replacement, dosing rate.

Mandatory Safety Instructions

Comply with safety instructions, use tools, protective clothing, goggles, and install safely.

Installation Precautions (Continued)

Chemical Handling and Hot Water

Consult distributor for compatible substances, hot water option 'T', temperature risks, warning signs.

User Responsibilities and Procedures

Read manual, check flow/pressure, adjust, determine ratio, check draw-up, change tube, relieve pressure, rinse.

Water Quality and Filtration

Install water filter (300 mesh) to prevent damage from abrasive substances.

Assembling the DOSATRON

Assembly Components and Tool-Free Process

DOSATRON delivered with bracket, suction tube, strainer. Assemble without tools.

External Injection (IE) Models

Suction Tube Assembly and Siphoning

Installation Hints and Flow Management

Filter Requirement for Warranty Validity

Install filter (300 mesh) upstream to prolong life and validate warranty.

Putting the DOSATRON into Order

Maintenance and Draining Procedures

Fitting and Injection Rate Adjustment

Injection Rate Adjustment Procedure

Adjust with no pressure. Turn off supply, unscrew blocking ring, adjust sleeve, tighten ring.

Conversions and Seal Maintenance

Changing Injection Assembly Seals

Annual replacement, no tools, clean seating, refit by hand, avoid twisting. Rinse before dismantling. Wear safety gear.

Seals and Valve Maintenance

Motor Piston Maintenance and Replacement

Motor Piston Replacement Procedure

Turn off supply, remove tube, unscrew part, pull dosing part. Various models shown.

Reference Designation System

Troubleshooting Guide

Motor Piston Troubleshooting

Covers piston stalled, air not bled, max flow exceeded, damaged piston.

Injection System Troubleshooting

Covers water backflow, no suction, air leak, blocked tube, worn seals.

Troubleshooting (Continued)

Under Injection and Leak Troubleshooting

Addresses suction air, valve seal, flow issues, plunger seal, stem, and various leak points.

Limited Warranty Information

Flow Rate Calculation Method

dosatron D 25 RE 2 Specifications

General IconGeneral
ModelD 25 RE 2
CategoryWater Pump
Max Pressure6 bar
Temperature Range4°C - 40°C
MaterialPolypropylene
Injection Ratio1:500 to 1:50 (0.2 - 2%)
Weight4 lbs (1.8 kg)