INSTALLATION HINTS
EXCESSIVE FLOW (as an indication)
If your DOSATRON clicks more than 40 times, that is 20 cycles in 15 seconds*,
you are close to the maximum flow limit. If you need more flow, you must
install a DOSATRON with a higher capacity of flow.
*D 25 RE 10 = 30 times, 15 cycles
The DOSATRON can be connected to
the main water line directly (Fig. 4) ;
on a by-pass (Fig. 5), recommended.
If your flow rate is above the opera-
ting limits of the DOSATRON, see
EXCESSIVE FLOW.
To prolong the working life of the
DOSATRON it is advisable to install a
filter (ex.: 300 mesh - 60 microns depen-
ding on your water quality) upstream.
This is imperative if the water contains
impurities or particles, especially if the
water comes from a well.
A filter is recommended and requi-
red for the warranty to be valid.
Installing the DOSATRON on
a bypass enables clean water to
be supplied without operating the
DOSATRON and the DOSATRON to
be easily dismantled.
When connecting an
installation to the public
water supply, you must res-
pect the rules and regulations
in force in the country.
Fig. 4
Check
valve
Valve
Valve
Filter
Filter
Fig. 5