DOSATRON INTERNATIONAL / 11
Under no circumstance should the solution level be above the water
inlet of the DOSATRON (to avoid siphoning situations).
Fig. 2
Fig. 3
WHAT YOU SHOULD DO
WHAT YOU MUST NOT DO
W
W
The DOSATRON is delivered with a suction tube (cut it to the needed length)
enabling its use with a large capacity concentrate container.
The tube must be fitted with its strainer and weights.
The instructions for fitting the tube are to be found in the specific chapter.
NOTE : The maximum suction height is 4 meters (13 vertical feet).
Fit the tube, equipped with its strainer and its weight, and immerse it in the
solution to be injected.
ASSEMBLING THE DOSATRON (cont...)
10 cm
4"
NO !
IMPORTANT ! - Do not put the suction tube strainer on the bottom of the
stock solution container. The strainer must be suspended at least 10 cm
[4”] above the bottom of the tank to avoid sucking up the insoluble par-
ticles that may damage the injection assembly (Fig.2).
- Do not put the strainer on the ground.