EasyManua.ls Logo

dosatron D3 RE 3000 - Storingen; Typenummering

dosatron D3 RE 3000
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
©
DOSATRON INTERNATIONAL / 157
NL
Typenummering
©
DOSATRON INTERNATIONAL / 157
©
DOSATRON INTERNATIONAL / 156
REF.
Serie #
Storingen
REF. : ............................................... Serie #: ...........................................
VOORBEELD D3 T RE/GL 2 IE BP V AF P II
Type DOSATRON
Temperatuur
RE : instelbaar
GL : Green Line (fertigation) [Groen]
Dosering (% of ratio)
IE = Externe injectie
BP: geïntegreerde bypass
V: viskeuze producten
( > 400 cPs)
Pakkingen/afdichtringen:
AF = PH 7-14
VF = PH 1-7
K = hooggeconcentreer
de zuren (> 15%)
Kleur: - = blauw [PP]
P = wit [PVDF]
R = rood [PP]
V = groen [PP]
J = geel [PP]
O = Oranje [PP]
Andere letters (raadpleeg ons)
PROBLEEM OORZAAK OPLOSSING
Zuigermotor
DOSATRON
start niet of stopt
Zuigermotor loopt niet Reset de zuiger met de
hand
De pomp is niet ontlucht Ontlucht de pomp m.b.v.
de ontluchtknop
Maximum doorstroming
overschreden
1. verlaag de
doorstroming, herstart
de pomp.
2. Draai het schrœfdeksel
los Verwijder de zuiger
en controleer of de
zuigerklepringen nog op
hun plaats zitten
Zuigermotor
beschadigd.
Stuur de pomp naar uw
servicecentrum terug
Dosering
Water stroomt
terug in de
concentraat tank
Vervuilde, versleten
ontbrekende delen of
van de terugslagklep.
Reinigen of vervangen.
Er wordt geen
concentraat
opgezogen
De zuigermotor is
gestopt
Zie bij zuigermotor
Lekke aanzuigslang Vervang aanzuigslang
Verstopte zuigslang of
aanzuigfilter
Reinigen of vervangen
Ontbreken of versleten
terugslagkleppakking
Reinigen of vervangen
Ontbreken of versleten
aanzuigpakking
Vervangen
Versleten zuigbuis Vervangen