SYMPTOM CAUSE SOLUTION
Leaks
Leaks in the vicinity of
the nut under the
pump body
Diffuser seal is
damaged or
positioned
incorrectly.
(Position correctly or) replace
it.
Leaks between the
setting sleeve and the
injector assembly
Doser body seal
damaged, positioned
incorrectly or
missing.
(Position correctly or) replace
it.
Leaks between the
body and bell housing
Bell housing seal
damaged, positioned
incorrectly or
missing.
Position correctly, clean the
seal seating or replace bell-
housing seal.
THE MANUFACTURER
DECLINES ALL RESPONSIBILITY IF THE DOSATRON
IS USED IN CONDITIONS THAT DO NOT CORRESPOND
TO THE OPERATING INSTRUCTIONS AS INDICATED
IN THIS MANUAL.