EasyManua.ls Logo

Dosmatic SUPERDOS 20 - Operation

Dosmatic SUPERDOS 20
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE:
RINSE INJECTOR AFTER EACH USE:
additive allowed to remain in injector can dry out and foul or damage lower end at the next
start up. Put suction tube into a 1 qt. (4 liters) or more container of fresh ltered water. Pull fresh
water through the injector by operating until container if empty. This procedure is not needed for
continuous operation.
BYPASS INJECTOR: When not in use put the injector in bypass mode by using the three valve
bypass (preferred) or the optional bypass lever on the injector.
CLEAN SUCTION TUBE FILTER SCREEN: Inspect each time new solution is added. Clean
as frequently as necessary by washing in fresh water. Remove lter screen (#27) from suction tube
(#25) and run water backwards through it. Replace if necessary. Keep lter screen off bottom of
solution container to prevent dirt and precipitate from contaminating solution.
STORAGE: For extended storage, rinse injector as described above and place entire injector
underwater (in 5 gal container). Monthly, apply a small amount (thimble full) of chlorine bleach to
avoid algae growth.
CLEAN SOLUTION CONTAINER: Keep covered to prevent dirt, ies, feathers and other y-
ing debris from entering container. rinse container thoroughly and often. Do not mix chemicals
together that might react and cause a precipitate. Use FILTERED WATER when lling container.
CLEAN INLET FILTER: Clean or replace inlet lter as required to increase the life of the unit
as well as reduce pressure loss.
REPLACE DOSAGE PISTON AND SHAFT SEAL: The injector is shipped with a spare Dos-
age Piston (44) and shaft seal (17), see Fig. 1, as these are normal wear parts, replace both when
solution injection is less than set amount.
8