The table below shows the technical characteristics of the console:
MagLink LX Technical Characteristics
Characteristic Value
Power supply 100 - 240 V~, 50-60 Hz
Consumption 15 VA
Operating temperature (-10 - +50) °C
Relative humidity (5 - 95)%, non-condensing
Number of probes
32 (16 probes through internal barrier and 16 probes with
added MagDirect modules)
Number of ON-OFF external sensors Up to 32
Number of ON-OFF internal sensors 6 (only when Dipswitch 2 is ON)
External relay outputs Up to 32
Internal relay outputs 4
Lower power of the relay output 0,5 A, 33 V~, or 2 A, 30 V DC
Output power for the probes
12 V DC, 100 mA per output for each probe, connectors MR3
MR4 (up to 8 probes for each connector)
Serial communication of the probes RS485
Host communication (management)
RS232 and TCP/IP (almost every forecourt controller have the
protocol integrated)
Printer communication RS232
Integrated web server for remote con-
figuration, consultation, com-
munication, and emails as well as
HOST COMMUNICATION
TCP/IP
GSM modem for SMS service 1 Optional
IFSF 1 Optional
Case Plastic
Protection IP40
Dimensions 265 x 190 x 95 mm