4.2 Correct Use
Only use the MagLink LX console for use as given in this manual. The console must be installed in a safe
arrea. The console includes an intrinsic safety barrier and two (2) channels (BRA-2SIP) to connect XMT-SI-
485 and DMP-IS-485 probes.
The table below shows the characteristics of use of the intrinsically safe barrier contained in the console:
MAGLINK LX Features (barrier) Description
Group (area of use) II (Surface industries different from mines)
Category and type of potentially explosive atmosphere (1) G
Protection mode ia
Group of substances (gases, vapours or mists) IIB
The specifications of use for console security and for the Barrier are given in this manual and on the product
label.
IMPORTANT: Safety instructions constitute an attachment to this manual and users must
acknowledge it before using the equipment.
WARNING: The Console must not be used in hazardous areas (because
there is a risk of fire and explosion). The probes of the XMT-SI-485 family are
installed in hazardous areas and must be connected to the Barrier contained
in the console.
4.3 Incorrect Use
Incorrect and alternative uses include:
l Resistive touch screen: Only use fingers or special tools made for resistive touchscreens to select
screen options.
l USB and USB Port devices: Only use this port for firmware updates, console backup and USB
printer connection.
l Serial ports: Only use the serial ports for printer and PC connection with management programs that
interface with the protocols given by Start Italiana S.r.l.
l Network cable: Only use the network cable connection for console configuration, and local network
connections (Refer to the M2051-EU Configuration manual).