SERVICE AND GENERAL MAINTENANCE (cont’d)
6.4. MAINTENANCE SCHEDULE
LANTEC recommends the following maintenance be carried out every 12 months or
after 500 hours of actual operation, whichever occurs first:
y Disconnect all hydraulic hoses, wire rope and remove the winch from its base,
taking note of its position and any shims used
y Disassemble the winch per the instructions in Disassembly / Assembly Section
y Inspect and replace any worn parts
y Assemble the winch per instructions in Disassembly / Assembly Section
y Refill with NEW Lubricating Oil
y Mount the winch on its foundation, making certain to install any shims in their
original position, reconnect hydraulic hoses and wire rope
y Follow start-up instructions in section 5. START-UP PROCEDURE.