C1
#29 (3.5mm)
1 1/2
[38.15]
5/32
[3.98]
1 1/2
[38.10]
2 9/16
[65.09]
2 3/8
[60.33]
5/32
[3.97]
1
2
PIECE #1
THICKNESS 3/32 (2.4mm)
PIECE #2
THICKNESS 1/8 (3.2mm)
INSULATION
COMBUSTION−CHAMBER
SPACER
NOZZLE #20
(4.1mm)
COMBUSTION−CHAMBER
NOZZLE
GROUND PLATE
PROTECTOR FOR
MINERAL WOOL
4 HOLES Ø7/16 [Ø11.10]
ON %%1 5/8 [Ø41.28]
4 HOLES Ø5/16 [Ø7.94]
ON %%1 5/8 [Ø41.28]
CA−N
ADJUSTMENT BURNER
CA & CAOPG NATURAL GAS
SUPPLY PRESSURE: 7" W.C. (20/25 Mbar)
MANIFOLD PRESSURE: 3.5" W.C. (8.75 Mbar)
IGNITION WIRE: 15"
DETECTION WIRE: 18"
HIGH LIMIT: 700° F
LOCKED: 600° F
THERMOSTAT: OMRON E5CS−X
BTU: 78 500 / 157 000