Input Voltage | 24 V DC |
---|---|
Weight | Approx. 1.2 kg |
Protection Class | IP65 |
Communication Interfaces | Ethernet |
Operating Temperature | -20 to +50 °C / -4 to +122 °F |
Dimensions | 144 x 144 x 118 mm |
Input Signal | 4-20 mA |
Data Logger | Integrated |
Power Supply | 24 V DC |
Enclosure | IP65 |
Essential safety guidelines and precautions for using the REGARD 7000 system.
Explains warning symbols, signal words, and consequences for user awareness.
Details text formatting and symbols used for document clarity and navigation.
Lists recognized brands and their owners relevant to the REGARD 7000 system.
Overview of REGARD 7000 as a modular gas/fire alarm control unit with distributed intelligence.
Details REGARD 7000's adherence to SIL2/SIL3 requirements and masterless architecture.
Lists all hardware components of the REGARD 7000 system with order numbers and software versions.
The base assembly for REGARD 7000 modules, managing power and communication.
Details the specifications and types of Docking Stations available.
Provides detailed technical specifications for the Docking Station 4/8 slots.
Introduces the diverse range of input, output, and communication modules for the REGARD 7000 system.
Describes the 4-20 mA Input Module and its HART® communication capabilities.
Explains the Modbus RTU Master Module for connecting Modbus RTU Slaves.
Details the Digital Input Module for connecting up to 8 digital input signals.
Describes the Relay Module for switching mains power loads.
Explains the Relay Module for switching 24 V DC loads.
Details the Gateway Module for outputting system data to higher-level systems.
Describes the Long Distance Gateway for connecting spatially remote Docking Stations.
Explains the Bridge Module for integrating existing REGARD systems.
Covers the function of the Slot cover for unused slots in a docking station.
Essential components for wiring electrical signals to system modules.
Details the 24-pole DC terminal block for specific module connections.
Details the 24-pole AC terminal block for specific module connections.
Details the 16-pole terminal block for specific module connections.
Details the 16-pole terminal block with resistors for specific inputs.
Details the 2/3-pole terminal blocks for various applications.
User interface hardware for system operation, monitoring, and data visualization.
Explains the use of licensable additional functions via add-on licenses.
Details the Advanced Dashboard 6RU with its screen and installation specifications.
Details the Advanced Dashboard PM with its screen and installation specifications.
Details the Standard Dashboard 3RU with its screen and installation specifications.
Process of designing the gas and fire alarm system by specialized engineers.
Explains the REGARD 7000's role as a central unit and its installation in switch cabinets.
Defines the maximum operational capacity and connectivity limits for a REGARD 7000 system.
Essential requirements for proper system structure setup, including connections and earthing.
Specific prerequisites for systems measuring flammable gases, oxygen, or toxic gases.
Discusses optional ring structure/double ring structure for enhanced communication security.
Step-by-step guide for the physical assembly and installation of the REGARD 7000 system.
Procedures and requirements for bringing the installed system into operational readiness.
Lists the prerequisites that must be met before commencing commissioning.
Describes the steps for preparing the system for operational readiness.
Details the procedure for powering on and starting the REGARD 7000 system.
Explains how to configure the REGARD 7000 system for its intended functions.
Procedures for user authentication and session management within the system.
Details the layout and interactive elements of the list view display.
Defines user roles and their corresponding access privileges and system functions.
Describes the two selectable view types for displaying input and output channels.
Details the navigation bar buttons used for scrolling through channels.
Explains the functions of various navigation buttons like Detail selection, Cancel, Filter, Sort.
Describes the elements present in the title bar of the channel display.
Explains the functions of buttons found on the menu bar.
Details the buttons used to select different views like input, output, or group views.
Explains the progress bar that shows system status and channel counts for alarms, faults, etc.
A comprehensive reference for icons used in the system interface and their meanings.
Illustrates the channel views corresponding to different module types.
Explains icons used in the status field for 4-20 mA input channels.
Explains icons used in the status field for relay output channels.
Explains icons used in the status field for Modbus output channels.
Explains icons used in the status field for bridge channels.
Explains how channel states are prioritized for display based on user importance.
Details how channel states are communicated visually through blink patterns and signals.
Details the side bar used for switching between ports and channels in menus.
Illustrates relay output behavior based on configured alarm confirmation modes.
Lists essential conditions that must be met before operating the REGARD 7000 system.
Specific prerequisites for systems measuring flammable gases, oxygen, or toxic gases.
Requirements for operating the system in compliance with NFPA 72 standards.
Specific requirements for operating the REGARD 7000 in maritime applications.
Details specific operational aspects when using REGARD 7000 with other REGARD devices.
Explains system responses to various input signal ranges and conditions.
Describes the role-based access control and user management features.
Outlines the functions available to users with the 'View only' role.
Outlines the functions available to users with the 'Operation' role.
Outlines the functions available to users with the 'Maintenance' role.
Outlines the functions available to users with the 'Configuration' role.
Outlines the functions available to users with the 'Administration' role.
Describes the default view and configuration display after logging in with the View role.
Instructions for acknowledging alarms or displaying detailed information while in operation.
Explains operations available to the Maintenance role, including system component checks.
Details the procedure for performing maintenance on Docking Stations.
Provides instructions for maintaining and restarting individual modules within the system.
Explains how to maintain channels and ports, including locking/unlocking them.
Guides on customizing the dashboard interface, including name, language, and display settings.
Details how to perform system configuration, parameter changes, and data management.
Outlines the general steps required to configure a Port within the system.
Explains how to enter the configuration mode for system settings.
Details the process of modifying system parameters within the configuration mode.
Describes how to assign unique names to modules within the system.
Explains how to export system configurations and generate reports.
Guides on saving and importing system configurations to/from USB storage.
Explains how to compare online or offline configurations with stored files.
Steps to compare online configurations via dashboard or software.
Steps to compare offline configurations with stored system files.
Explains how to copy port configurations using a wizard for efficiency.
Guides on selecting connected transmitters using the device wizard.
Guides on selecting the measured gas for transmitters via a wizard.
Details how to set the measuring range parameters for channels using a wizard.
Explains the channel parameter menu for the 4-20 mA Input Module / HART®.
Details the configuration settings for the Modbus RTU Master Module.
Explains the channel parameter menu for the Digital Input Module.
Details the configuration settings for Gateway Modules.
Explains the channel parameter menu for the Bridge Module.
Describes how to allocate REGARD system card numbers to Bridge Module channels and ports.
Guides on customizing the dashboard interface, including name, language, and display settings.
Outlines administrative tasks such as user management and firmware updates.
Describes how to create, delete, and manage user accounts and their roles.
Explains how to configure automatic login for specific user roles.
Provides instructions for updating the dashboard firmware.
Guides on installing new add-on licenses for enhanced functionality.
Explains how to manage the internal library of PDF documents on the dashboard.
Instructions for safely powering down the dashboard unit.
Comprehensive list of common system faults, their causes, and troubleshooting remedies.
Specific error codes and messages related to HART® communication and components.
Step-by-step procedures for replacing or adding modules to the system.
Procedure for replacing a faulty transmitter with a new unit.
Information on extending or modifying the system within its operational limits.
Overview of the configuration software and steps for setting up an account.
Explains the software's operating concept and details the program interface layout.
Instructions for modifying system configurations and transferring them.
Describes the offline and online modes for using the configuration software.
Lists applications that can be processed in offline configuration mode.
Lists applications that can be processed in online configuration mode.
Guides on creating, saving, importing, and comparing system configurations.
Details how to receive configuration data from the REGARD 7000 and send data to it.
Explains how to compare online or offline configurations with stored files.
Steps to compare online configurations via dashboard or software.
Steps to compare offline configurations with stored system files.
Procedures for saving, saving as a copy, and opening configuration files.
Guides on setting and changing parameters within configurations.
Explains how to copy port configurations using a wizard for efficiency.
Guides on selecting connected transmitters using the device wizard.
Guides on selecting the measured gas for transmitters via a wizard.
Details how to set the measuring range parameters for channels using a wizard.
Guides on creating and saving component and parameter reports.
Explains how to display the Dashboard screen and its functions.
Guides on selecting the correct PC interface for system connection.
Instructions for changing the display language of the configuration software.
Guidance on the environmentally responsible disposal of the product.
Specifies the operational and storage environmental conditions for the system and dashboard.
Lists dimensions, weight, and system response times for various components.
Definitions of technical terms, abbreviations, and device modes used in the manual.
Lists REGARD cards compatible with the bridge module for system integration.
Details Modbus command formats, register assignments, and data type meanings.
Explains command setup for PROFIBUS DP and PROFINET masters interacting with REGARD 7000.
Official statement confirming the product's compliance with relevant EU directives.