EasyManuals Logo

Draytek Vigor2912 User Manual

Draytek Vigor2912
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #364 background imageLoading...
Page #364 background image
Vigor2912 Series User’s Guide
354
Event Code – Use the drop down menu to specify an event
to perform the test.
Last Inform Response Time – Display the time that
VigorACS server made a response while receiving Inform
message from CPE last time.
CPE Client
Such information is useful for Auto Configuration Server.
Enable/Disable – Allow/Deny the CPE Client to connect
with Auto Configuration Server.
Port – Sometimes, port conflict might be occurred. To
solve such problem, you might change port number for
CPE.
Username and Password – Type the username and
password that VigorACS can use to access into such CPE.
Periodic Inform Settings
The default setting is Enable. Please set interval time or
schedule time for the router to send notification to CPE. Or
click Disable to close the mechanism of notification.
STUN Settings
The default is Disable. If you click Enable, please type the
relational settings listed below:
Server IP – Type the IP address of the STUN server.
Server Port – Type the port number of the STUN server.
Minimum Keep Alive Period – If STUN is enabled, the
CPE must send binding request to the server for the purpose
of maintaining the binding in the Gateway. Please type a
number as the minimum period. The default setting is “60
seconds”.
Maximum Keep Alive Period – If STUN is enabled, the
CPE must send binding request to the server for the purpose
of maintaining the binding in the Gateway. Please type a
number as the maximum period. A value of “-1” indicates
that no maximum period is specified.
Apply Settings to APs
This feature is able to apply TR-069 settings (including
STUN and ACS server settings) to all of APs managed by
Vigor2912 at the same time.
Disable – Related settings will not be applied to VigorAP.
Enable – Above settings will be applied to VigorAP after
clicking OK to save the configuration. If such feature is
enabled, you have to type the password for accessing
VigorAP.
AP Password – Type the password of the VigorAP
that you want to apply Vigor2912’s TR-069 settings.
After finishing all the settings here, please click OK to save the configuration.