DriSteem VAPORSTREAM VLC 9-1 Specifications

General IconGeneral
ModelVAPORSTREAM VLC 9-1
TypeElectric Steam Humidifier
Phase1
Humidification Capacity9 lb/h (4.1 kg/h)
Steam Output9 lb/h (4.1 kg/h)
Voltage208-240V
Water Connection1/2 in. NPT
Drain Connection1/2" NPT

Summary

Vaporstream Electrical Specifications

Selecting a Location for the Vaporstream

Locating the Humidifier

Considers factors like ambient temperature, noise, access, and connections for humidifier placement.

Vaporstream Mounting

Mounting Methods

Details various methods for mounting the Vaporstream humidifier securely and level.

Water Supply, Drain, and Condensate Piping Overview

Drain Piping

Alternate Water Seal and Drain Valve Piping

Describes an alternate piping configuration to reduce water seal height for closer floor mounting.

Water Supply Piping

VLC Model (Standard Water)

Details water supply piping for the VLC model, including strainer, needle valve, and fill solenoid.

VLDI Model Water Supply Piping

Explains water supply piping for VLDI models using a float valve and optional end-of-season drain.

Vaporstream Wiring

Electrical Installation Requirements

Covers branch circuit protection, wire sizing, and grounding per NEC/IEC standards.

Service Disconnect Requirements

Mandates installation of a service disconnect per NEC/governing codes.

Wiring Requirements and Torque

Details wire length limits, routing, and component torque specifications.

European Wiring and Disconnect

Specifies European wiring requirements and disconnect location guidelines.

Dispersion: General Instructions

Selecting Dispersion Assembly Location

Guidance on choosing the best location for dispersion assemblies for optimal absorption.

Dispersion: Interconnecting Piping Requirements

Dispersion: Single Tube and Multiple Tube

Dispersion: Rapid-sorb

Dispersion: SDU-I

Dispersion: SDU-E

Dispersion: Area-Type Fan

Vaporstream Start-Up Procedure

Operation and Maintenance: Vaporstream VLC Standard Water Models

Inspection and Maintenance Procedures

Details annual and seasonal inspection and maintenance tasks for VLC models.

Operation and Maintenance: Vaporstream VLDI Models

Cool Down Before Maintenance

Procedures for safely cooling down the humidifier before performing maintenance.