The conserver mu
st:
Always maintain a backup supply of oxygen (i.e.
compressed cylinders and regulator).
WARNING (Cont.)
Lint and dust can contaminate the oxygen path and create a
fire hazard. Keep all oxygen connections clean and free from
lint and dust.
Do not wet the area of the oxygen inlet connection, the
disinfectant residue may create a risk of fire.
Make sure the fill valve, if equipped, is clean and free of
dirt, debris, oil or other contaminants.
Do not submerge the conserver in the disinfectant,
wipe disinfect only.
Be used only after one or more settings have
been individually determined or prescribed for you at
your specific activity levels.
Be used with a specific combination of parts and
accessories (i.e. cannulas, tubing) that meet the
specifications of the conserver manufacturer, and that
were used while your settings were determined.
Your prescribed settings should be periodically reassessed
by a physician or other appropriately licensed healthcare
practitioner for effectiveness of therapy.
Use only parts and accessories recommended by the
manufacturer to ensure proper function and to avoid the
r
isk of fire
and burns.
Not intended for use with any humidification devices.
Do not attempt to open or remove enclosure. There are no
user-serviceable internal components.
Not for use with an endotracheal tube or tracheostomy
.
Close supervision is necessary when the nasal cannula is
Cannula tubing can pose a strangulation risk and
tripping hazard.
Locate tubing away from areas of high
foot traffic and keep children and pets away from cannula
tubing.
It is unsafe to use accessories, detachable parts and
materials not described in the instructions for use,
interconnect this equipment with other equipment not
described in the instructions or modify the equipment.
used by impaired persons or near children.
The proper placement of the nasal cannula in the nose
is critical to the consistent operation of this equipment.
Donot use cannula tubing that is longer than
7 ft. (2.13 m).
To reduce the risk of rapid oxygen recompression and fire,
open the oxygen source valve slowly and completely so the
pressure gauge moves slowly as it indicates the oxygen
source pressure.
MR Unsafe. Do not bring the device or accessories into
aMagnetic Resonance (MR) environment as it may cause
unacceptable risk to the patient or damage to the
conserving device or MR medical devices. The device
andaccessories have not been evaluated for safety in an
MR environment.
WARNING (Cont.)
The settings of other models or brands of oxygen therapy
equipment do not correspond with the settings of th
e
CTOX-MN02
Electronic Oxygen Conserver.
Choking Hazard - The 870 post seal washer may pose
a
choking hazard. Small parts not for children under 3years
or any individuals who have a tendency to place inedible
objectsin their mouths.
Before using this unit, make certain that your hands arefree
of oil, grease
and other contaminants,
and that the
cylinder
is secure in an upright position.
5