Model VF61_____________________ SN:______________________
Code
No.
Function
Abbrev.
Function setting item
Unit
Setting range (Setting Resolution)
Change
during
operation
Default
User
value
26 Lim.Torq (P) Power torque limit % 20 to 150 Possible 150%
27 Lim.Torq (B) Braking torque limit % 0 to 150 Possible 150%
28 DC-Br.V
DC brake voltage (/rating
x 100
% 0 to 20 Possible 0%
29 DC-Br.F
DC brake start frequency
at time of deceleration
stop
Hz .5 to 10 Possible 1 Hz
30 DC-Br.Time
DC brake time at the time
of deceleration stop
Sec 0 to 5 Possible 0 Sec
31 Jump.1.F Jump (1) Frequency Hz 0 to Top.F Possible 0 Hz
32 Jump.2.F Jump (2) Frequency Hz 0 to Top.F Possible 0 Hz
33 Jump.3.F Jump (3) Frequency Hz 0 to Top.F Possible 0 Hz
34 Jump.F.Band Jump frequency band Hz 0 to 10 Possible 0 Hz
35 SAcc.St.Sel
S-shape acceleration
start selection
Sec 0 Sec (a)
Impossible
(a)
36 SAcc.End.Sel
S-shape acceleration end
(settling) selection
Sec 1 Sec (b)
Impossible
(a)
37 SDec.St.Sel
S-shape deceleration
start selection
Sec 5 Sec (c)
Impossible
(a)
38 SDec.End.Se
S-shape deceleration end
(settling) selection
Sec 10 Sec (d)
Impossible
(a)
39 Rotation.Sel
Rotation direction
selection
N/A
For/Rev Both Both forward and reverse
allowed (a)
For only reverse rotation is inhibited
(b)
Rev only Forward rotation is inhibited
(c)
Impossible (a)
40 IPF.Restart
’Restart after
instantaneous power
failure’ selection
N/A
off ower failure lasting 10 seconds or less is *
(a)
on assumed to be instantaneous power failure
(b)
Impossible (a)
41 Restart.Time Restart time Sec
.1 to 5 sec.
Impossible 1 Sec.
42 Retrial.Cnt Retry count N/A 0 to 5 Impossible 0
43 F.Control
Frequency control mode
selection
N/A
Standard Open control
(a)
Slip Compen. Slip conpensation control
(b)
Freq. Droop Frequency droop control
(c)
ASR Control ASR control
(d)
Impossible (a)
44 Droop
Frequency droop quantity
(expressed as % of
Top.F)
% 0 to 10% Impossible 0%
45 PGM.Drive
Program operation
selection
N/A
off (a)
on (b)
Impossible (a)
46 PGM.Time.Se
Program operation time
unit selection
N/A
sec. Second
(a)
min. Minute
(b)
hour Hour
(c)
Possible (a)
47 PGM-0.Time
Program operation (0)
time
N/A 1 to 1000 Possible 1
48 PGM-1.Time
Program operation (1)
time
N/A 0 to 1000 Possible 0
49 PGM-2.Time
Program operation (2)
time
N/A 0 to 1000 Possible 0
50 PGM-3.Time
Program operation (3)
time
N/A 0 to 1000 Possible 0
51 PGM-4.Time
Program operation (4)
time
N/A 0 to 1000 Possible 0