Chapter 3
3.6 Arming the System with a 2-Way Wireless Key
If configured, the PowerSeries Neo system can be armed using the following wireless keys:
l PG4929/PG8929/PG9929
l PG4939/PG8939/PG9939
To Arm the System with a 2-way wireless key
l Press the desired Arming mode button anytime the system Ready indicator is on.
3.7 Bypassing Zones
WARNING!If a zone is not operating properly contact a service person immediately.
Bypassing zones intentionally unprotects specified zones the next time your system is armed. Depending on the type of keypad,
bypassed zones will be identified differently. Using an HS2LCD series keypad, bypassed zones are indicated on the LCD screen as
shown in the following table. If using an LED or ICN series keypad, the will light and the bypassed zones #s will be shown.
LCD Display Indication Description
Zone Label <>
none Zone is ready for arming.
Zone Label <>
O
O Zone is currently open. You may be unable to arm the system.
Zone Label <>
B
B Zone is bypassed.
LCD Keypad Zone Indications
Bypassed zones:
l Must be configured before arming the system.
l Can be done using a keypad or SMS.
l Allow for access to protected areas when the system is armed.
l Allow you to arm the system if a zone is temporarily out of service.
l Reduce the level of security.
l Will not sound an alarm.
l Are automatically cancelled each time the system is disarmed.
l Can be programmed together within bypass groups. For more information see Bypass Groups”.
3.7.1 Additional Bypass Features
RecallLastBypass Recalls all zones that were bypassed the last time the bypass zone feature was used.
BypassAllOpen
Zones
Allows the user to quickly bypass all open zones with a single command.
ClearBypass Instantly clears all bypass conditions from the zones assigned to the partition.
Programminga
BypassGroup
Use when you consistently bypass the same zones. This feature allows you to store in memory one
group of bypassed zones per partition.
ActivatingaBypass
Group
Loads a stored bypass group from memory.
Note:Ensure that no zones are unintentionally bypassed when arming your system.
Note:24-hour zones can only be unbypassed manually.
Note:For security reasons, your installer has programmed the system to prevent you from bypassing certain zones (e.g., smoke
detectors). For more information on fire zones seeFire and CO Zone Types”.
To Bypass Individual Zones LCD Display
1. Press [*] to enter the function menu.
Press (*) for <>
Zone Bypass
2. Press [*] or [1]. If required enter your [access code] or present your proximity tag.
Zone Bypass <>
(*) To Bypass
3. Directly bypass zones by entering their [3 digit zone #]. If using an LCD keypad
press [*].
OR
Scroll to the desired zone using the keys and press [*].
Zone 1 <>
0
4. To toggle and unbypass a zone reenter the [3 digit zone #] or press [*] again. To
bypass more zones repeat steps 3 and 4.
Zone 1 <>
B
5. To exit bypassing mode press [*].
- 11 -