[382] Third Communicator Options
*This option must remain OFF for SIA-FAR installations.
** A Call Waiting Cancel on a non-Call Waiting line will prevent successful connection to the central station.
DLS Downloading
[401] Downloading Option Codes
[402] DLS Downloading Telephone Number (32 Digits)
|____D___|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|
[403]-[404] DLS Downloading Access Code / Panel ID Code (Enter 6 Hexadecimal Digits)
[405] Answering Machine Double Call Timer
Default 060 (001-255 seconds)
[406] Number of Rings to Answer On
Default 000 (001-255 rings)
[499] Initiate PC-Link Downloading
Enter [499][Installer Code][499]
Opt Def ON OFF
1
R
Contact ID Partial Closing Identifier is “5”
9
R
Contact ID Partial Closing Identifier is “4”
2
R
Alarm Communications Enabled During Walk Test*
9
R
Alarm Communications Disabled During Walk Test
3
R
Communication Cancelled Message Enabled (ON for SIA CP-01)
9
R
Communication Cancelled Message Disabled
4
R
Call Waiting Cancel Enabled**
9
R
Call Waiting Cancel Disabled
5
R
T-Link Interface Enabled
9
R
T-Link Interface Disabled
6
R
AC Failure Transmission Delay is in Hours
9
R
AC Failure Transmission Delay is in Minutes
7
R
For Future Use
9
R
8
R
For Future Use
9
R
Opt Def ON OFF
1
R
Answering Machine/Double Call enabled
9
R
Answering Machine/Double Call enabled
2
9
R
User Can Enable DLS Window
R
User Cannot Enable DLS Window
3
R
Call Back Enabled
9
R
Call Back Disabled
4
R
User Initiated Call Up Enabled
9
R
User Initiated Call Up Disabled
5
R
Auto Event Buffer Upload Enabled
9
R
Auto Event Buffer Upload Disabled
6
R
For Future Use
9
R
7
R
For Future Use
9
R
8
R
For Future Use
9
R
Panel Default [403] Downloading Access Code [404] Panel ID Code
PC1616 161600
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|
PC1832 183200
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|
PC1864 186400
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|