[6] [P] Key Bell Options
ON = [P] Key Audible Alarm.
The BELL output will be activated when the [P] Key is
pressed and held for 2 seconds.
OFF = [P] Key Silent Alarm.
The BELL output will not be activated when a [P] Key
Alarm is generated.
[7] Transmission Back-up Options
ON = Call First Telephone Number Only.
When events programmed to report to the First
Telephone Number are to be transmitted, up to eight
attempts will be made to communicate to the First
Telephone Number. If all eight attempts to communicate
fail, a Failure to Communicate Trouble will be generated.
OFF = Back-up to Second Telephone Number.
If eight attempts to communicate to the First Telephone
Number fail, up to eight attempts will be made to
communicate to the Second Telephone Number. If all
eight attempts to communicate to the Second Telephone
Number fail, a Failure to Communicate Trouble will be
generated. Do not select Back-up to Second Telephone
Number if a Second Telephone Number is not
programmed is section [03]. Also, refer to section [33]
Communicator Call Direction Options.
[8] One Time Use Code Option
ON = One Time Use Code Enabled.
Access Code 16 may be used to disarm and then later
arm the system only once. After the One Time Use Code
is used to arm the system, it will be deleted and will not
be able to arm or disarm the system.
OFF = One Time Use Code Disabled.
Access Code 16 functions as a normal Access Code.
[19] 2nd System Option Code
Refer to section [18] First System Option Code for
programming instructions.
[1] Bell Pulse Options
ON = Bell Pulses for All Alarms.
The bell or siren will pulse for all types of alarms.
OFF = Bell Pulses for Fire Alarm Only.
The bell or siren will pulse for Fire and [F] Key alarms.
For all other audible alarms, the bell or siren will sound a
steady alarm.
[2] Master Code Options
ON = Master Code Not User-Changeable.
The Master Code may not be changed by the user, and
may only be programmed in the Installer’s Programming
Mode.
OFF = Master Code User-Changeable.
The Master Code may be programmed by the user using
the [
Q][5][Master Code] command. The Master Code
may also be programmed in the Installer’s Programming
Mode.
[3] Bell Squawk Options
ON = Bell Squawk on Arming and Disarming.
The bell or siren will sound a single squawk when the
system is being armed, and a double squawk when the
system is being disarmed.
OFF = No Bell Squawk.
The bell or siren will not squawk when the system is
armed or disarmed.
[4] PC16OUT Options
ON = PC16OUT Module Enabled.
A PC16OUT module may be connected to the control
panel; refer to the PC16OUT Installation Sheet.
OFF = PC16OUT Module Disabled.
The system will not support the use of a PC16OUT
Module.
[5] Telephone Line Monitor Trouble Options
ON = TLM Generates Trouble Condition.
A Telephone Line Monitor Trouble will generate a trouble
indication; the “Trouble” light will come ON and the
keypad sounder will beep until the [
Q][2] View Trouble
Conditions Command is entered.
OFF = TLM Generates Alarm When Armed.
When the system is disarmed, a Telephone Line Monitor
Trouble will generate a trouble indication as described
above. If the system is armed, a Telephone Line Monitor
trouble will generate an audible alarm on the bell or
siren.
[6] Radionics Handshake Frequency Selection
ON = 1400Hz Handshake.
The system will accept handshake tones at 1400Hz
when using Radionics communications formats.
OFF = 2300Hz Handshake.
The system will accept handshake tones at 2300Hz
when using Radionics communications formats.
Consult with the monitoring station to determine which
communication formats and handshake frequencies are
required.
[7] Telephone Line Monitor Disabled / Enabled
ON = Telephone Line Monitor Disabled.
The TLM function will be shut off and telephone line
troubles will not be indicated by the system.
OFF = Telephone Line Monitor Enabled.
The TLM function will be active and the system will report
telephone line troubles by indicating Trouble Condition 4
when using the [
Q][2] View Trouble Conditions
Command.
[8] Bypass and Access Code Options
ON = Access Code Required to Bypass Zones.
After entering the [
Q][1] Bypass Zones Command, an
Access Code must be entered before zones may be
bypassed.
OFF = Access Code Not Required to Bypass Zones.
Enter the [
Q][1] Bypass Zones Command to bypass
zones.